Technical Specifications
Product Advantage
1, Air curtain isolation design, to prevent internal and external cross-contamination, air flow 100% outflow, negative pressure vertical laminar flow.
2, Move the glass door up and down, can be arbitrarily positioned, easy to operate, and can be completely closed for sterilization, positioning height limit alarm prompt.
3, The work area power output socket, equipped with a waterproof socket and sewage interface for the operator to provide great convenience
4, Exhaust with a special filter, control emission pollution.
5, The working environment adopts high-quality 304 stainless steel, smooth, seamless, no dead angle, can be easily and thoroughly disinfected, and can prevent the erosion of corrosive agents and disinfectants.
6,Led LCD panel control.
7,Equipped with high efficiency filter failure alarm function.
8,Work area airflow diarrhea alarm.
9,10 ° tilt angle, in line with the concept of human design
Product Description
-
Structural features
Purificationtable by box, fan, high efficiency filter, operating switch and other majorcomponents. The box body is made of color steel plate,the surface is sprayed with plastic, and the working table is made of stainlesssteel. The purification unitadopts the fan system with adjustable air volume. By adjusting the workingstate of the fan, the average wind speed in the clean working area can be keptwithin the rated range, and the service life of the HEPA filter can beeffectively extended.
The working principle of
Theair passes through the primary filter, is pressed into the static pressurechamber by the centrifugal fan, and is filtered through the hePA filter andblown out from the air outlet surface to form a clean air flow. The clean airflow flows through the area requiring purification with uniform cross sectionwind speed, taking away the dust in the area, thus forming a high cleanlinessworking environment.
Install and use
The biological clean safety cabinet should be in place in a cleaner environment in the work room (preferably placed in the 100,000 grade or 300,000 grade primary purification room), plug in the power supply, according to the function shown on the control panel can be opened, before starting the biological clean safety cabinet should be the working area surface and shell of the careful cleaning treatment, remove the surface area dust, ten minutes after booting can be implemented normal operation.
Maintenance
1, according to the actual use of the filter,regularly remove the initial filter for cleaning, the cleaning cycle isgenerally 3-6 months. (If it is not cleaned for a long time, the dustaccumulation will affect the insufficient air intake and reduce the cleaningeffect.)
2. When the air filter of the primary filteris normally changed or cleaned, and the ideal cross-sectional wind speed cannotbe reached, the working voltage of the fan should be adjusted to achieve theideal uniform wind speed.
3, generally after the use of eighteen whenthe fan working voltage is adjusted to the highest point, still can not reachthe ideal wind speed, it means that the high-efficiency filter dust is too much(the filter hole on the filter material has been basically blocked, to beupdated in time), the general high-efficiency air filter service life is eighteenmonths.
4. When replacing the high-efficiency airfilter, attention should be paid to the correctness of the model specificationsand sizes (the original manufacturer configuration), according to the arrowwind direction device, and pay attention to the peripheral sealing of thefilter, absolutely no leakage phenomenon occurs.
FAQ
-
1.We are based in Guangdong, China, start from 2021,sell to Africa(30.00%),South Asia(15.00%),Mid East(10.00%),Domestic Market(10.00%),North America(5.00%),South America(5.00%),Eastern Europe(5.00%),Southeast Asia(5.00%),Oceania(5.00%),Eastern Asia(5.00%),Western Europe(5.00%),Central America(5.00%),Northern Europe(5.00%),Southern Europe(5.00%). There are total about 51-100 staffs in our office.
2. How can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;
3.What can you buy from us?
Test kit,In Vitro Diganositc,Disposable Samplers,Rapid test kits,Swab
4. Why should you buy from us not from other suppliers?
We focus on producing virus nucleic acid detection kits, Disposable samplers, IGG/IGM rapid test kit, PCR test kit etc.The products approved CE, FDA, SGS, ISO13485.More than 200 staffs, 10 production line.
5. What services can we provide?
Accepted Delivery Terms: FOB,CFR,CIF,EXW;
Accepted Payment Currency:USD,EUR,HKD,CNY;
Accepted Payment Type: T/T,Credit Card,PayPal, Western Union,Escrow;
Language Spoken:English,Chinese,Spanish,Japanese,Portuguese,German,French,Russian,Korean
6.Can I have samples of this goods to test the quality?
Yes, free sample is available.
7.What's the delivery time and can you lower the price?
It depends on your order. The delivery time is within 3-4 days. If you have large quantities,the price and delivery time can be negotiable.
8.Can I customize the packaging and the logo?
Yes, we could offer customized logo for you.
9.What's the shipping method?
We often use DHL, FedEx, UPS, TK,EK,LH to ship our products.
10.The PCR test kit is required to be stored at a temperature between -25 degrees Celsius and -15 degrees Celsius. How did you do it?
Most of our PCR detection reagents are transported in an incubator, and the temperature can be maintained at -20 degrees Celsius for about 12 days, which can fully meet the general air transportation time limit.